JawChecker™
Computer-assisted recording of jaw movement
What it is: The JawChecker measures how the lower jaw moves relative to the upper jaw, using two small sensors attached directly to the teeth, with no recording linkage and no facebow.
What it is for: dental functional diagnostics and therapy, the assessment of temporomandibular joint disorders, the individual programming of the articulator and the provision of the measurement data for CAD/CAM software. It automatically detects jumps in the condylar path such as those caused by disc displacement and reduction.
Operation: The software also understands spoken commands, in many languages. It gives its answers either as text or through audio output.
No more recording linkage. Precisely measured.
On the right, a real condylar path plays back with disc displacement on opening and reduction on closing, just as the software shows it. The click sound can be switched on.
Universal capabilities
- Kinematic hinge axis
- Condylar paths in 6 planes
- Disc findings with click detection
- Bennett angle and path inclination
- Settings for common articulators
- Real-time playback
- Import of older JAWS recordings
- Link to practice software (VDDS)
- Data export to CAD/CAM, e.g. exocad
- Runs on macOS and Windows
- Ten languages, voice control
Two sensors instead of a linkage on the head
Conventional electronic recording systems need extraoral components that are attached to and aligned on the patient's head. The JawChecker does without it.
Conventional recording
- Extraoral recording linkage
- Time-consuming mounting and alignment on the head
- Linkage in front of the patient's face
- High purchase cost
JawChecker™
- No linkage, no facebow
- Two small sensors, quickly attached
- Face unobstructed, natural movement with occlusal surfaces left free
- Far more affordable, with very precise measurement
How the JawChecker measures
One sensor sits on the lower jaw, the second on the upper jaw. They are aligned to the occlusal plane and measure acceleration and angular rate. Because the upper jaw is measured as well, the JawChecker records the movement of the lower jaw relative to the upper jaw. The data go to the practice software wirelessly.
Attach the sensors
Fix the sensor carriers to the upper and lower jaw; the system is detected automatically.
Rest phase
Hold still for two seconds. The system measures the sampling rate and the zero level of the sensors.
Move on the signal tone
Opening, protrusion, mediotrusion right and left. Spoken instructions guide through the recording.
Analysis
Kinematics, condylar paths, joint parameters and disc findings are produced automatically after the recording.
What the software calculates from a recording
The measurement data can be analysed and displayed in different ways: as condylar paths in six planes, as an incisal point trace, as velocity and acceleration over time, as articulator settings, and as playback in real time or point by point.
All values apply per side. Graphics and measurement records are linked in the patient menu.
Modern software design: the JAWS software runs on macOS and Windows: a clear, calm interface with numbered work steps from the hinge axis to data transfer, patient search, voice control, spoken instructions and ten languages. Click an image to enlarge it.
Kinematic hinge axis
Position right and left, the basis for all condylar paths.
Condylar paths in 6 planes
Freely performed movements, optionally with the intercondylar connecting line.
Protrusion
Sagittal condylar path inclination from protrusion, evaluated between 0.3 and 7 mm of advancement, mean of several advancements.
Mediotrusion
Bennett angle and path inclination per side.
Incisal point
Path of the incisal point, also for imported recordings.
Velocity and acceleration
As a trace below the curves, with adjustable smoothing.
The click where it happens on the path
The software detects jumps in the condylar path and classifies them as disc displacement or disc reduction. The point is marked in all planes and reported as a finding, read aloud on request.
Displacement
Lateral jump with a change of track in cranial direction. Located initially, intermediately or terminally.
Reduction
Deceleration, deviation caudally, jump anteriorly, then a more caudal track.
Reciprocal clicking
The incursive click is always the opposite of the excursive click on the same side.
- Playback in real time or four times slower – the marker appears only when the curve reaches the point
- Click sound through the loudspeaker – also for incursive clicks
- Scanning with mouse or arrow keys – magnifier 1–10×
- Condylar path inclination only from click-free sections – with a warning whenever clicking is involved
- Treatment suggestion for the finding – review before adopting and change if needed
Settings for semi- and fully adjustable articulators
From the measured joint parameters, the software compiles the values for the most widely used articulators. Hovering over the list immediately shows a picture and the settings of the instrument.
| Parameter | Movement | Unit | Side |
|---|---|---|---|
| Sagittal condylar path inclination | Protrusion | ° | right / left |
| Bennett angle | Mediotrusion | ° | right / left |
| Path inclination, mediotrusion | Mediotrusion | ° | right / left |
| Hinge axis position | Opening / closing | mm | right / left |
Including Artex, Denar, Panadent and Stratos.
Fits what you already have
Existing recordings remain usable and patients need not be entered twice.
Older recording systems
Import of JAWS recordings from Freecorder BlueFox and Condylocomp LR3, with suitable smoothing for each system.
Practice software
Patient data via the VDDS interface, patient search by number or name.
CAD/CAM
Data transfer to common CAD/CAM software such as exocad.
Operation
Ten languages, voice control, spoken instructions and a tooltip on every control.
The fourth generation
The JawChecker is now the fourth practice-ready recording device we have developed. The first, the STRING-LR-Recorder of 1981, was the world’s first practice-ready electronic method for recording jaw movement. Each of these devices was the standard of recording technology in its time and is still ready for use today.
STRING-LR-Recorder
1981, presented at the congress of the International Academy of Gnathology in Venice. The world’s first practice-ready electronic recording method.
Condylocomp LR3
Electronic recording of the condylar paths.
Freecorder BlueFox
Recordings still usable in the software today.
JawChecker™
Two small sensors, no more recording linkage.
JawChecker training courses
Course leader: the inventor of the JawChecker, Dr. Dr. Rolf Klett, Würzburg, physicist and experienced practising dentist, specialist in functional diagnostics and therapy certified by the DGFDT (German Society for Functional Diagnostics and Therapy) of temporomandibular joint disorders, with decades of teaching courses worldwide.
Dates will be announced.
If you are interested in a course or an information event, please leave your contact details (name, practice, phone or e-mail). We will let you know as soon as the dates are set.
Dentron GmbH
Would you like to know more about the JawChecker? Request further information material. Please include your contact details.
- Company
- Dentron GmbH
- Address
- Eduard-Buchner-Straße 8
D-97204 Höchberg - Phone
- +49 171 3808800
- info@dentron.com
- Web
- www.dentron.com
Information pursuant to § 5 DDG (German Digital Services Act)
Provider
Dentron GmbH – Dentale Meß- und Informationssysteme
Eduard-Buchner-Straße 8
D-97204 Höchberg
Contact
Phone: +49 171 3808800
E-Mail: info@dentron.com
Web: www.dentron.com
Represented by
Managing director: Dr. Dr. Rolf Klett
Commercial register
Register court: Amtsgericht Würzburg
Register number: HRB 1912
VAT ID
VAT identification number pursuant to § 27a of the German VAT Act (UStG): DE 134169012
Trademark
JawChecker™ is a trademark (application filed). Patent pending.
The JawChecker is not yet certified as a medical device.
Privacy policy
Controller
The controller for data processing on this website is Dentron GmbH, Dr. Dr. Rolf Klett, Eduard-Buchner-Straße 8, 97204 Höchberg, Germany, phone +49 171 3808800, e-mail info@dentron.com.
Visiting the website
This site sets no cookies, uses no analytics or tracking tools and loads no content from third-party servers (no fonts, videos or maps). When the site is accessed, the web server processes technically necessary data such as IP address, date and time, page requested and browser type in order to deliver the site and keep it secure (Art. 6(1)(f) GDPR). The website is hosted by STRATO GmbH, Otto-Ostrowski-Straße 7, 10249 Berlin, Germany. IP addresses are anonymised in the server log files, and the log files are deleted after six weeks at the latest.
Contacting us
If you contact us by e-mail or phone, we process your details to handle the enquiry and any follow-up questions (Art. 6(1)(b) or (f) GDPR). They are not passed on without your consent. The data are deleted once no longer needed; statutory retention periods remain unaffected.
SSL/TLS encryption
This site uses SSL/TLS encryption. You can recognise an encrypted connection by “https://” and the padlock symbol in your browser’s address bar.
Your rights
You have the right to access, rectification, erasure and restriction of processing of your data, to data portability, and to object and to withdraw consent given (Art. 15–21 GDPR). Please contact the controller named above.
Right to lodge a complaint
You may lodge a complaint with a data protection supervisory authority. The authority responsible for Dentron GmbH is the Bavarian State Office for Data Protection Supervision (BayLDA), Promenade 18, 91522 Ansbach, Germany.